Detail Specifications
Overall Depth:
2.406 inches
Bolt Circle Diameter:
7.000 inches
Mounting Hole Diameter:
0.218 inches
Mounting Hole Quantity:
3
Overall Diameter:
7.374 inches
Case Surface Treatment:
Enamel
Usage Design:
For use w/acetone, air, benzine, benzol, boric acid, brine, butane, butyl alcohol, glycerine, nitrogen, steam/up to 400 psi/, tannic acid, water and other liquids and gases not corrosive to bronze
Graduation Unit:
100.0 pounds
Actuation Type:
Single bourdon tube
Adjustability:
Nonadjustable
Scale Range:
+0.000/+800.000 pounds pressure per square inch
Scale Range:
+0.000 to 800.000 pounds pressure per square inch
Scale Smallest Increment:
10.0 pounds
Connection Type:
External
Mounting Method:
Flush panel
Scale Accuracy:
1/2 in. Entire range
Actuating Element Material:
Phosphor bronze
Scale Inscription/background Color:
Black figures on white background
Connection Location:
Back
Protective Crystal Material:
Glass
Connection Size:
1/2 in. Npt
Connector Type Vent:
Not provided
Reference Number Differentiating Characteristics:
Underload stop
Manufacturer Part Numbers
No other part numbers with same form, fit, and function found.